Flow Control Valves VF-50

Features

  • A screw-in, cartridge-style, adjustable orifice, pressure-compensted, manually-operated,bypass-type hydraulic flow regulating valve .it can be used as a priority-type flow regulator or a restrictive-type 2-way flow regulator when the bypass port is blocked.
  • The VF maintains a constant flow 3 rate from regardless of load pressure changes in the system downstream of 3, or in the bypass leg at 2. Reverse flow ( 3 to 1 ) bypasses the control orifice
  • The regulated flow increases form closed to fully open, with counter-clockwise rotation of the knob.
  • Note: When used as a bypass flow control in applications where the priority flow port will be blocked by external valving, bypass pressure drop will increase unless a small amount of leakage is provided for the priority port. Consult factory

Inquiry
PDF
  • Specifications
  • How to Order
Model Number Operating Pressure Maximum Flow Weight
VF-50 248 (3597 psi) 49 (12.94 gpm) 0.75 (1.65 lbs)
Fluid Type ISO VG 32, 46, 68
Viscosity 10~400 (59~1854 SSU)
Operating Temperature -15~70 (-5~158oF)
Contamination Level ISO4406. 21/19/16 NAS1638,10